Key function – dissuading thermal losses down. Warmth needs to go up in the warmth for pex tubes. It can run from any type of products allowed the building as a thermal protecting layer for use in the building and construction of gender.From whatever material is carried out layer of insulation have to fulfill the following condition:

The thermal resistance of the insulation layer need to be more than the complete pex tubing thermal resistance of the home heating layers (consisting of completing covering, pex tubing) with a maximum warm tons of Radiant Floor Home Heating. The higher the home heating tons, the thicker layer of insulation.The greater the thermal resistance of the completing covering, the thicker layer of insulation.

One of the most common insulation product in modern building and construction is Pex polystyrene. We suggest making use of Pex polystyrene thickness of not less than 35 kg/m3 (pex tubes). Pex Polystyrene reduced density is not immune to mechanical tension, is ruined when not utilized very carefully, and also sheds its mechanical and thermal shielding buildings, specifically versus the backdrop of the continuous civil engineering works is a very long time from completion of the pipeline assembly units pex tubing Glowing Floor Heating water to fill their headphones. Pex Polystyrene density of 50 kg/m3, in addition to extrusion, is used in systems with high mechanical lots (automobile facilities, storage facility complexes with hefty loaders, heated roads, etc.).

Enhancing textile. Pex Bed rails

Reinforcing mesh action as well as the cell diameter of bar strengthening mesh is chosen on the basis of flooring building, based upon the functions of the facilities (pex tubes ), its destination, lots, etc. In the standard style for much easier installment utilized a grid, typically with a cell 150×150 mm, pole 4-5 mm. Falls on Pex polystyrene is a genuine cause for the format contours water Radiant Floor Heating. Pex Piping are attached to the grid with plastic bolts.

To provide extra toughness screed in many cases is dual support: a second layer of strengthening mesh is placed on the contours of water pipes Radiant Floor Heating. Pex Rails in Europe due to the big spread of type piling “snake” is extensively used installing rails and also clips, which are set up on polystyrene.

Often taking care of enhancing mesh and/or mounting rails used Pex U-shaped supports. Pex pipe contours vschelkivaetsya mounting imprison the slots (pex tubes ports). In this situation, apply one layer of reinforcement, are laid over the pipes.

Pex Damping tape

Damping tape is put around the boundary of the facilities before putting concrete. Offers to compensate for thermal expansion of concrete ties during home heating. It is produced, normally polyethylene foam size of 100-120 mm and a density of 8-10 mm.

Pex Water lines

Pipes contours Radiant Flooring Home heating piled in accordance with the illustration (draft Water Glowing Flooring Home Heating). The number of meters of the pipeline is recorded and recorded in the table balancing storage tank, connected to the task. Based upon the evidence of mounting structural engineer picks the requirement to adjust the tuning (harmonizing) of the pex tubing table. As a rule, unlike the real size of pipe from the project by up to 10%, the modification harmonizing tank is not called for.

Hydrotesting

Before loading the contours of water Glowing Floor Heating concrete is advised to examine the system for rigidity. Checking the system is performed based on national structure laws. Usually, the system inspects the pressure of 3.4 bar for 24-hour.

When filling up Pex coolant system regular opening and also closing circuits. Acquire total elimination of air from Pex pipes and also tools.

It is recommended to leave the system of Radiant Floor Home heating under pressure on the whole program of the continuing to be civil design jobs (tool couplers, mounting ending up finishes), periodically checking the level of pressure that, at any kind of phase make sure that during the manufacturing of other jobs, not a leakproof system.

Concrete screed

Pouring concrete is executed after placing the contours of water Radiant Floor Home heating as well as testing activities. The density of the screed need to go to least 30mm above the pipeline, mark the concrete suggested no less than the M-300 (V-22, 5). In diplomatic immunities (large weight and/or thermal tons on the heating range, etc.) thickness of concrete connections and brand name designers calculated based upon the characteristics of the object (in this situation necessarily is a separate calculation of the home heating panels). The minimal thickness of screed (30mm above the pipeline) is attributable largely to not-strength characteristics, and also to accomplish harmony of temperature distribution on the surface of the heating panels.

When the thickness of screed over 150mm needs separate estimations of the thermal routine of the Pex heating panel with the introduction of special correction aspects.

For recommendation: the weight of 1 square meter of connections with the 50 mm thickness is 350-400 lb.

The higher the density of the connection the more time is needed to present it on a secure home heating routine from the moment of inclusion.

Thicker screed amounts to better immersion system. The lower the thermal conductivity of connections, the greater the called for temperature level of the coolant.

Countervailing joints If, about the great level of the home heating panel, it is divided (every 15 meters) partly of offsetting sutures, television, the back-crossing seam is laid in a safety corrugated tube (300mm on the left as well as right of the seam extension). It is advised to pack home heating circuits undamaged within a compensatory land, ie development joints must cross only stress and also return piping circuit.

The system of warm water allows the use of any plasticizers in concrete. Commonly made use of in modern-day building and construction has gotten a gadget with plastic connection fibrils.